Active Harmonic Filter |
Active Harmonic Filter-
Active Harmonic filters use IGBT fired circuits to mitigate harmonic distortions in the load or the network of loads where they are installed. They can be separately installed on prominent individual loads generating harmonics or combined AHF unit on mains. The combination of both can also be used. It all depends on level of harmonics, type of operational issue for which it is being installed or level of compliance to standards as per utility / distribution company.
Active Harmonic Filter eliminate harmonic injected into the mains supply by non-linear loads. Its response time is extremely fast and is connected in parallel to the load which is to be compensated.
Technical Specification-
Active Harmonic filters use IGBT fired circuits to mitigate harmonic distortions in the load or the network of loads where they are installed. They can be separately installed on prominent individual loads generating harmonics or combined AHF unit on mains. The combination of both can also be used. It all depends on level of harmonics, type of operational issue for which it is being installed or level of compliance to standards as per utility / distribution company.
Active Harmonic Filter eliminate harmonic injected into the mains supply by non-linear loads. Its response time is extremely fast and is connected in parallel to the load which is to be compensated.
Technical Specification-
Rating
|
30A
|
60A
|
100A
|
150A
|
200A
|
300A
|
400A
|
500A
|
600A
|
Input Voltage Range |
415V, 3 Phase + N (+10%, -20%)
| ||||||||
Input Freq. Range |
50Hz (±10%) (60Hz, Optional)
| ||||||||
Capacity |
30A
|
60A
|
100A
|
150A
|
200A
|
300A
|
400A
|
500A
|
600A
|
Harmonic Filtering |
Non zero sequence 2nd to 5th harmonic compensation,
Attenuation ratio up to 96% | ||||||||
Enclosure Protection |
IP40
| ||||||||
Installation |
Floor mounting Cable Entry from Bottom
| ||||||||
Accustic Noise Legel |
< 65 dBA
| ||||||||
Operating Temp. |
0 to 45 Deg. C
| ||||||||
Relative Humidity |
upto 95% (non-condensing)
|
* 200 mm free space below and above required for air ventilation. Floor mounting with air ventilation rack
Dimenison in mm- | |||||||||
Rating |
30A
|
60A
|
100A
|
150A
|
200A
|
300A
|
400A
|
500A
|
600A
|
Height |
1000
|
1000
|
1750
|
1750
|
1750
|
1750
|
1750
|
1750
|
1750
|
Width |
620
|
620
|
800
|
800
|
800
|
800
|
1000
|
1000
|
1000
|
Depth |
450
|
450
|
800
|
800
|
800
|
800
|
850
|
850
|
850
|
For more details :http://www.powerqualityindia.com/harmonic-filteration.html
Contact us :http://www.powerqualityindia.com/contact-us.aspx
Contact us :http://www.powerqualityindia.com/contact-us.aspx